Tech. Checks
This is a list of some common problems.
Washers
Drains
In all the years that we have done service, by far the most common problem with
washer failure is in the drain system. Either the valve fails, or there
is blockage in the line somewhere.
Here's how to check:
Run
a standard wash cycle (preferably empty); the water should begin filling, and
there should be no water running out the drain.
This is easy to check on an open sump type drain, all you have to do is follow
the drain line going into the sump (a little bit of water is normal).
For a closed drain system, you would simply look in the drum to see if the
water level is rising.
The water should shut off once it reaches wash level, if it doesn't, and water
level hasn't risen inside the drum, then chances are you either have a bad
drain valve, or some things jammed in the valve holding it open, in which case
you will need to check the line(s).
If the water level rises and the water does not shut off (make sure your not
running a flush cycle) the water level switch(es) could be bad (or it could be
the air-line(s) going to the switch(es) sometimes they get plugged or cracked).
Another thing that will cause the water to run continually is if the water
valve sticks on (this being second most common problem) usually the water will
continue to run even when the machine is turned off.
Just about any size washer should drain in a 30-40 Seconds. So as it goes into
a drain count how many seconds it takes for the drum to empty. If it goes
beyond a minute, chances are you have something caught in the drain line or
drain valve.
Water Valves:
If you have a water valve stuck on chances are it needs a rebuild kit.
Sometimes you can get away with taking it apart and clearing any debris that
might be causing it to hang open. Before ordering a new rebuild kit make
sure the seat inside the valve body is not cracked (if it is, then the whole
valve will need to be replaced). Sometimes you can free up a valve just
by tapping on it. If that doesn't work you can try turning off the water
valve. (The problem with this is, if it's a hot valve, you will only be
able to run cold cycles) some machine have more than one hot, and more than one
cold valve. (I've seen housekeeping staff run a garden hose to the hot water
heater and fill it manually too.)
Machine
won't start (nothing comes on: display or lights)
First step, check that the breaker or disconnect is on (or that the line fuses
are OK - even though line fuses shouldn’t be used. . .) If that's ok, check for
power where it goes into the machine (j-box) you'll have to use a volt-meter
for that one.
If power going into the machine is there, check the control fuses (these are
the glass type fuses) be sure to turn power off before checking them. If
you look hard enough you'll find one or two control fuses (usually on the
outside of the machine - Milnors hide there's inside. . .Wascomats hide there's
in the back, Uniwash UW's are on the side, unimac UF's are in the front inside
the cover-plate, and UC's, SC's, HC's & AT's are under the top cover).
It may also be that the on/off switch is no good.
Machine won't start (Display
and/or lights do come on)
Even though the display lights up, and lights come on, the circuit breaker or
line fuse(s) may still be bad. Most machines run on a 3 phase system
(that's 3 separate 120V lines) the motors use all three lines, however, the
controls (lights, display, water valves, drain valves, computer) only use one
or two of these 120V lines. So a bad circuit breaker may only be giving
two of the 120V lines instead of three. And likewise, if one of the line
fuses (these are the big copper ones) has blown, the controls will work, but
the motors won't turn. So be sure to check these first. If they
check out OK, then it may be in the door interlock switch(es) (this would be
the switch(es) located somewhere close to where the door closes) sometimes the
switch hangs up or goes bad.
It may also be the start switch (more usually the case with UC's, HC's, AT's
& SC'c, Wascomats and Milnors. (This would be a good low-cost spare part to
have on hand (see the rec. spare parts list) because it's a whole lot easier to
replace it that it is to test it)
If the machine is a newer Uniwash UW series; they install a magnet where the door
handle is, this magnet trips the door interlock switch. Most people do
not even know it's there (until they get hit with the service call) this magnet
breaks off sometimes so be sure to check it.
Drum won't turn
This is usually just a broken belt (and most of the time, you can hear the
motor turning even though the belt is broken).
Motor contactors going bad is a common service call. Most of the time though,
they give you some warning because they get noisy before they fail. To check
open the cover to the motor contactors (usually the top cover), start the
machine and watch the contactors to see if they are pulling in, if they are, it
still may be a contactor (there are two parts to a contactor: the coil and the
contacts. The coil pulls the contactor in, and the contacts provide power
to the motor) you will need to use a voltmeter to check voltage going into the
contactor (I've had more that a few wires come loose from a contactor) and the
voltage going out. If you have the voltage in, but not out, it's the
contactor. If you have voltage out, it may be a bad motor, see the motor
tech. check page.
IMPORTANT NOTE: If you determine that it is a bad motor and it's an 'Elmo'
motor, and you are going to try and have it rewound at a motor rewind shop: be
sure that the shop is familiar with that procedure (Elmo motors are European
motors... they use a metric winding (not S.A.E.) and they have to be wound by
hand, not by a machine) if a shop tries to do otherwise the motor will only
last 2-3 months at best.
Alarms on the Uniwash UW's
& UF's
The Uniwash UW's and UF's have alarm codes. Below is a list of these
alarms and what they mean.
Fill Alarm:
This alarm sounds when the machine doesn't fill with water in a certain amount
of time (usually 5 Min.) This could be a faulty drain valve (see above) or
water valve turned off, or a water fill hose (the one that comes from the wall)
is plugged causing reduced water flow (most water hoses have screens - they
plug up over time). It may also be a faulty level switch or plugged
air-line (read the drain section above)
Empty Alarm:
This alarm sounds when the machine hasn't emptied in the correct amount of time
(usually 1 min.) this is usually the drain valve (see the above drain section).
Water Alarm:
This alarm sound when water is trapped in the machine, it won't let you open
the door to prevent flooding the room. This is caused by a faulty or
plugged drain. If you don't see any water in the machine then it's most
likely a level switch or the air line that goes to it plugging up.
Over-temp Alarm:
This alarm sounds when the computer is getting faulty readings from the
temperature sensor. It needs to be replaced. It's located in the
sump; 2 wires go to it; red and black - to get to it you will need to remove
the front panel.
Dryers
No Heat (Drum Turns)
This is by far the most common dryer problem of all-time. It's usually a bad
glow-bar or ignition cable, depending upon the type of ignition system that you
have.
Glow-Bar Type Ignitions
The glow-bar system sends electric current through a heating type of element
until it glows hot enough to light the gas (this is used on most older style
dryers) An I.R. sensor (infrared sensor) determines when the glow-bar is hot
enough to light the gas, it then sends a signal to the gas valve to turn on.
To test this system, open the front cover where the burners are; start the
dryer in the heat cycle; you should see the glow bar getting red hot (the glow-bar
sits inside the burner box just above the burner tubes - there are two types; a
round one that has spirals, and a flat one that looks like half of a coat
hanger except smaller. If you have a hard time identifying them go look at the
pictures of them in the store section) If nothing glows you will need to take a
voltage reading across the glow-bar leads (there are 2) as you first start the
dryer. No voltage means it's something else. Voltage means replace
the bar (a replacement glow-bar should be kept in stock).
If the glow-bar lights and does not go off then the I.R. Sensor has
failed. (I usually replace the glow-bar along with the I.R. sensor
because one will take the other out, and it's just good maint. procedure to do
as such.)
If the glow-bar lights for about a minute then goes off and you do not hear a
click sound come from the gas valve (this click sound is the coil in the gas
valve opening) then it's probably a bad gas valve coil (see below). If
the glow-bar lights, then turns off (in about a minute) and the gas valve
clicks on (and you can hear and/or smell that the gas valve is open) the burner
tube holes are plugged and/or the glow-bar needs to be adjusted closer to the
burner tube. To clean the burner tubes, you can either shoot compressed
air into them, or remove them and run water through them. If it's an
older dryer it's best to remove them and run water through them so as to get
all the compressed lint completely out.
Spark Ignition Type
If you have a spark ignition (looks like a spark plug wire from a car...in fact
it is.) The way that this system works is, instead of lighting the gas with a
glow-bar, it lights it with a spark. To test the system, open the burner
cover, turn the dryer on in heat mode, you should hear the gas valve click, and
the spark igniter sparking, (in fact, it may even light the gas, but then goes
right back off.) If this is the case then most likely the ignition cable
is bad. Most people think that just because they can hear the spark, and see
the gas light that the cable is OK, however, the ignition module sends a small
amount of voltage the opposite direction through ground, through the fire, and
through the high voltage ignition cable back to the ignition unit to let it
know that the gas has lit. If the ignition cable has a even the slightest crack
in the carbon core cable; that small amount of voltage cannot jump that crack
like the higher voltage.... So replace the cable. (if it's a weekend and your
faced with a downed dryer; either buy one from an auto parts store, or borrow
one from someone's car...) The other thing that it may be is plugged
burner tubes, if it looks like there is a lot of lint in the burner compartment
you may want to try blowing out the burner tubes or removing them and rinsing them
out with water.
Gas Valve Coil
If you do not hear the gas valve click (as mentioned above) and you do have
spark or the glow-bar is cycling on and off, then odds are that the coil on the
gas valve is bad (most gas valves have 2 coils as a redundant safety feature)
in all my years of service I've only replaced a couple of entire gas valves,
it's always been the coils that sits on top of it. The coil can be replaced as
a unit (4 -screws hold it on) it usually has 2 or 4 wires going to it.
(It's rec. that this be one of the parts you keep on hand because alot of times
repair techs get back ordered on them). Be sure to shut off power and gas
before replaced and mark your wires.
Sail-Switch
The other common problem associated with a no heat condition is when the sail
switch fails to pull in. The sail switch pulls in when the dryer is
started via the air circulation. If the circulation gets reduced either
from heavy lint build up on the lint filter or a blocked exhaust vent the sail
switch won't close all the way and the heat circuit will shut down. (I use to
work in San Francisco, CA and the homeless people would dry their clothes over
the exhaust vents on the roof or in the alleys which caused these sail switches
to open and shut off the heat circuit...i.e. service call) Another thing that
happens alot is the maids would either clean behind the dryers or store stuff
behind them knocking the sail switch out of alignment without knowing it (alot
of sail switches are behind the dryer about a foot above the ground).
There is an adjustable weight on the sail switch, the proper way to adjust it
is: with the dryer off, move the weight just enough so that the slightest
movement will cause the switch to click on (switch should not be tripped when
dryer is off). Test it by running the dryer, the air circulation should
pull it closed.
High Limit Switch
For years American Dryers put these high limit switches in their machines that
had reset buttons on them (look inside the lint compartment - just under the
basket) If the dryer got too hot the switch would trip. If this is the
case be sure to check the temp. (I would always replace the temp. sensor
whenever there was any doubt just to be safe.)
The other thing with American and Cissell dryers was that the connections would
always come loose inside the lint compartment (housekeeping staff would knock
them loose actually when they would go to clean them) so be sure to check them.
Thermodisks
Thermodisks are heat sensors that are about the size of a nickel or quarter
with two screws. They are placed in lint compartments, burner boxes, and
exhaust vents. When they heat up to a preset temp. they will open up
(electricity won't flow through them) when the dryer is cold you can check them
with a continuity meter (turn power off).
Ignition Modules
I have had a fair amount of ignition modules fail. All you have to do is take a
voltage reading on them when the dryer is first started in the heat
cycle. Voltage will be displayed on ignition module tag (24VAC, 120VAC,
220VAC) If there isn't any voltage to the module follow the circuit to
see if there is a transformer in the it (Cissell dryers actually put fuses on
their transformers for years) I've had a lot of transformers go bad (especially
24V)
Dryer In-Op (Nothing comes on)
Check circuit breaker. If it's a 220V machine be sure you have all legs
of your power.
Check your neutral leads (I can't tell you how many times I've seen wire nuts
come loose...) I've also had alot of power cords (especially 120V) go bad;
check them.
Check control fuses, there's usually more than one. Sometimes they put them in
the computer control board.
If there is a transformer in the main circuit (There may be two-one for the
heat circuit, the other for the control circuit) be sure to make sure you have
incoming and out going voltage according to the schematic voltage or it should
say on the transformer.
Dryer In-op (Lights come on, Basket won't turn)
Make sure door switch is adjusted properly or hasn't failed.
Check belt or chain.
Check the conduit going into the motor, sometimes older motors get hot and the
mount fails causing them to rotate in their craddle and pulling out the conduit
and wires. After repairing the wires you can run a large hose clamp
around the motor so as to secure it. This will keep you going long enough
until it's replaced.
If the dryer works only while you hold the start button on, it means the start
circuit in the motor has failed (120V - 220V single phase system) I've seen
people put tape over the button, however this should only be a temp.
fix...replace the motor. For a three phase system, it's most likely the
start relay is bad.
Be sure to check the main start contactor, these seem to fail quite frequently,
they are usually located behind the dryer in the rear control panel.
Speed
Queen Discount Parts, Speed Queen Parts, Speed Queen motors, Speed Queen
Discount motors, Commercial Speed Queen Motors, Discount Commercial Speed Queen
Parts, Commercial Speed Queen Discount Parts, Commercial Speed Queen Parts,
Discount Hays valve, Discount Hays water valve, Discount Hays water valves,
Hays water valves, Wholesale Hays water valves, Wholesale Hays steam valves,
Discount Parker valve, Discount Parker steam valve, Discount Parker water
valves, Discount Parker water valve, Wholesale Parker water valves, Wholesale
Parker Steam Valves, Hays Steam Valves, Parker rebuild kits, Hays rebuild kits,
Solenoid valves, 2-way solenoid valves, Parker solenoid valves, Hays solenoid
valves, Discount Parker solenoid valves, Discount Hays solenoid valves, Unimac,
Uniwash, UW, UF, UC, UM100, UM202, UM300, Huebsch, Speed Queen, Maytag, IPSO,
OPL, Commercial, industrial washers, dryers, extractors, Laundries, Discount
Uniwash Motors, Hays valve, Hays Valve kits, Parker valve, Parker Gold Ring
Series, Parker Gold Ring series 25, H5, Parker Gold Ring series S, 22,23,
Parker Valve, two-way piloted valve, Parker rebuild kit, Dependo drain valve,
Allen Bradley inverter drive, HIM unit, Parameter unit, gotronic rotation
detector, Gas Valve coil, Ignition Module, spark ignition module,door solenoid,
contactor, microswitch, Elmo motor, Keypad, WE6, WE5A,WE5B, Output board
| Next > |
|---|